- Lithium Golf Cart Battery
- Forklift Lithium Battery
-
48V
- 48V 210Ah
- 48V 300Ah
- 48V 420Ah (949 x 349 x 569 mm)
- 48V 420Ah (950 x 421 x 450 mm)
- 48V 456Ah
- 48V 460Ah (830 x 630 x 590 mm)
- 48V 460Ah (950 x 421 x 450 mm)
- 48V 460Ah (800 x 630 x 600 mm)
- 48V 460Ah (820 x 660 x 470 mm)
- 48V 500Ah
- 48V 560Ah (810 x 630 x 600 mm)
- 48V 560Ah (950 x 592 x 450 mm)
- 48V 600Ah
- 48V 630Ah
-
48V
- 12V Lithium Battery
12V 150Ah Lithium RV Battery
Bluetooth App | BCI Group 31
LiFePO4 Lithium
Discharge Temperature -20°C ~ 65°C
Fast Charger 14.6V 50A
Solar MPPT Charging - 24V Lithium Battery
- 36V Lithium Battery
- 48V Lithium Battery
-
48V LiFePO4 Battery
- 48V 50Ah
- 48V 50Ah (for Golf Carts)
- 48V 60Ah (8D)
- 48V 100Ah (8D)
- 48V 100Ah
- 48V 100Ah (Discharge 100A for Golf Carts)
- 48V 100Ah (Discharge 150A for Golf Carts)
- 48V 100Ah (Discharge 200A for Golf Carts)
- 48V 150Ah (for Golf Carts)
- 48V 160Ah (Discharge 100A for Golf Carts)
- 48V 160Ah (Discharge 160A for Golf Carts)
-
48V LiFePO4 Battery
- 60V Lithium Battery
-
60V LiFePO4 Battery
- 60V 20Ah
- 60V 30Ah
- 60V 50Ah
- 60V 50Ah (Small Size / Side Terminal)
- 60V 100Ah (for Electric Motocycle, Electric Scooter, LSV, AGV)
- 60V 100Ah (for Forklift, AGV, Electric Scooter, Sweeper)
- 60V 150Ah (E-Motocycle / E-Scooter / E-Tricycle / Tour LSV)
- 60V 200Ah (for Forklift, AGV, Electric Scooter, Sweeper)
-
60V LiFePO4 Battery
- 72V~96V Lithium Battery
- Rack-mounted Lithium Battery
- E-Bike Battery
- All-in-One Home-ESS
- Wall-mount Battery ESS
-
Home-ESS Lithium Battery PowerWall
- 24V 100Ah 2.4kWh PW24100-S PowerWall
- 48V 50Ah 2.4kWh PW4850-S PowerWall
- 48V 50Ah 2.56kWh PW5150-S PowerWall
- 48V 100Ah 5.12kWh PW51100-F PowerWall (IP65)
- 48V 100Ah 5.12kWh PW51100-S PowerWall
- 48V 100Ah 5.12kWh PW51100-H PowerWall
- 48V 200Ah 10kWh PW51200-H PowerWall
- 48V 300Ah 15kWh PW51300-H PowerWall
PowerWall 51.2V 100Ah LiFePO4 Lithium Battery
Highly popular in Asia and Eastern Europe.
CE Certification | Home-ESS -
Home-ESS Lithium Battery PowerWall
- Portable Power Stations
Understanding Voltage Levels and Battery Capacity: A Comprehensive Guide to 48V Batteries
When managing a 48V battery system, understanding the voltage levels and their implications on battery capacity is crucial. This article delves into key aspects such as voltage readings at different states of charge, charging requirements, and battery maintenance to provide you with a thorough understanding of 48V batteries.
What Voltage Represents 50% Charge in a 48V Battery?
Determining the exact voltage that signifies a 50% charge for a 48V battery can be complex due to variations in battery chemistry and design. Generally, for a 48V lead-acid battery, a 50% state of charge (SOC) is typically around 51.0 to 51.5 volts. This range is derived from the standard voltage discharge curves of lead-acid batteries, where 50% SOC indicates that the battery has used approximately half of its available energy.
For Lithium-Ion Batteries
For lithium-ion batteries, which are often used due to their higher efficiency and longer lifespan, a 50% charge typically corresponds to approximately 48.0 volts. Lithium-ion batteries have a flatter discharge curve compared to lead-acid batteries, making their voltage readings at different SOCs more consistent.
Full Charge Voltage of a 48V Battery
The full charge voltage of a 48V battery depends on the type of battery:
- Lead-Acid Batteries: Fully charged lead-acid batteries typically reach a voltage of 54.4 to 55.2 volts. This figure can vary slightly based on the specific battery type (e.g., flooded, AGM, or gel) and the charging system used.
- Lithium-Ion Batteries: For a fully charged 48V lithium-ion battery, the voltage is usually around 54.6 to 54.8 volts. Lithium-ion batteries maintain a more consistent voltage across their charge cycle compared to lead-acid batteries.
Charging Requirements for 48V Batteries
Charging a 48V battery system requires adherence to specific voltage ranges to ensure optimal performance and battery life:
Gel Batteries
For gel batteries, the peak charging voltage ranges from 55.2 to 56.6 volts. It is crucial to avoid exceeding this voltage to prevent damage to the battery cells.
Lead-Acid Batteries
The charging voltage for standard lead-acid batteries should be set between 55.2 to 56.4 volts for peak efficiency. This ensures the battery reaches full charge without overcharging, which can lead to reduced battery lifespan.
Lithium-Ion Batteries
Lithium-ion batteries typically charge to a maximum of 54.6 volts. These batteries charge quickly and efficiently, usually completing the process in less than 4 hours.
Float Voltage and Maintenance
To maintain a 48V battery system in a ready-to-use state, a float voltage is applied:
- For lead-acid batteries, the float voltage is approximately 54.2 volts. This voltage maintains the battery’s charge level and compensates for self-discharge without overcharging the battery.
- Lithium-ion batteries have a float voltage that is generally managed by the battery management system (BMS) to ensure safe and efficient operation.
Maximum Voltage for a 48V System
The maximum voltage for a 48V system can be context-specific:
- In telecommunications and similar systems, the maximum continuous voltage is typically -60 volts, with transients up to -100 volts being acceptable.
- For most standard 48V battery systems, including solar and backup power systems, the maximum safe voltage should not exceed 56 volts to avoid damage and ensure system safety.
Battery Duration and Capacity
The duration a 48V battery can last depends on its capacity and load:
- A typical 48V battery with a nominal capacity of 5600 watt-hours (Wh) under a 10 amp load at 120V AC would last approximately 4.6 hours. This estimate helps in planning the power needs based on battery capacity and load requirements.
Charging a 48V Golf Cart
A 48V golf cart battery needs to be charged when it drops to 30-35 volts. Regular charging ensures the battery remains in optimal condition and prevents excessive discharge that could shorten its lifespan.
Solar Panels for 48V Battery Charging
To effectively charge a 48V battery using solar power:
- A solar array should consist of panels capable of producing a total voltage in the range of 60-90V DC. This voltage range matches the charging requirements for a 48V battery and ensures efficient charging.
- The wattage of the solar panels must also be appropriate to the battery’s amp-hour capacity to achieve effective and timely charging.
Charging Time for a 48V Lithium-Ion Battery
48V lithium-ion batteries can typically reach a full charge in less than 4 hours, thanks to their efficient charging characteristics. This rapid charging capability allows for minimal downtime and optimal use of the battery’s energy.
Voltage for 50% DOD in Gel Batteries
For gel batteries, a Depth of Discharge (DOD) of 50% generally corresponds to a voltage of around 12.00 volts per 12V cell. This translates to 48.00 volts for a 48V system, ensuring the battery is neither over-discharged nor excessively stressed.
Conclusion
Understanding the voltage levels at various states of charge and the specific requirements for charging and maintenance is essential for managing a 48V battery system effectively. Whether dealing with lead-acid, lithium-ion, or gel batteries, adherence to recommended voltage ranges and charging protocols will ensure optimal performance, longevity, and reliability of your battery system.